Nortel DMS-100 Series Maintenance Manual page 119

Remote line concentrating module with extended distance capability
Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

Clearing a PM LCM critical alarm
At the MAP terminal
1
To silence an audible alarm, type
>MAPCI;MTC;SIL
and press the Enter key.
2
To access the PM level of the MAP display, type
>PM
and press the Enter key.
3
To identify the RLCM-EDC that has faults, type
>DISP STATE CBSY LCM
and press the Enter key.
If response
does not indicate CBsy LCMs
indicates CBsy LCMs
4
To post the RLCM-EDC with the alarm condition, type
>POST LCM CBSY
and press the Enter key.
Note: Record the name and number of the posted RLCM-EDC.
5
To identify central side (C-side) links to the host Line Trunk Controller PLUS
(LTC+), type
>TRNSL C
and press the Enter key.
Example of a MAP response:
Link 0: LTC 1
Link 1: LTC 1
6
To post the host LTC+, type
>POST LTC ltc_no
and press the Enter key.
where
ltc_no
is the number of the LTC+ (0 to 255) in step 5
RLCM-EDC alarm clearing procedures 5-5
Do
step 11
step 4
2; Cap MS; Status: SysB
6; Cap MS; Status: SysB
DMS-100 Family Maintenance Manual ABSK007
PM LCM
critical
(continued)
;MsgCond: CLS
;MsgCond: CLS