Nortel DMS-100 Series Maintenance Manual page 186

Remote line concentrating module with extended distance capability
Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

5-72 RLCM-EDC alarm clearing procedures
PM RMM
minor
(continued)
5
6
7
8
297-8381-550 Standard 02.02 April 1999
To identify the remote line concentrating module with extended distance
capability (RLCM-EDC) with links busied by the system (SYSB), type
>TRNSL C
and press the Enter key.
Example of a MAP response
LINK
0:
LCM REM1 00 0
LINK
1:
LCM REM1 00 0
To post the LCM from step 5, type
>POST LCM site cabinet lcm
and press the Enter key.
where
site
is the site name of the RLCM (alphanumeric)
cabinet
is the number of the RLCC cabinet
lcm
is the number of the LCM
CAUTION
If you do not allow the time required for the system to
clear the alarm, a false alarm indication occurs.
Allow 3 to 5 m for the system to clear the alarm
before you proceed to the next step.
To identify the peripheral-side (P-side) links that have defects, type
>TRNSL P
and press the Enter key.
Example of a MAP response:
LINK 0: RMM 0 0;CAP MS;STATUS:SysB,;MSGCOND: CLS
LINK 1: RMM 0 1;CAP MS;STATUS:
To busy the link that has defects, type
>BSY LINK link_no
and press the Enter key.
where
link_no
is the number of the the P-side link that has defects from step 7
0;CAP MS;STATUS:SysB,;MSGCOND:CLS
1;CAP MS;STATUS:
OK,;MSGCOND: OPN
OK,;MSGCOND:OPN