Nortel DMS-100 Series Maintenance Manual page 231

Remote line concentrating module with extended distance capability
Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

Replacing an NT2X59 card in RMM
At your current location
1
Proceed if:
a step in a maintenance procedure directs you to this card replacement
procedure
you use the procedure to verify or accept cards
your maintenance support group directs you to this procedure.
2
Obtain a replacement card. Make sure that the replacement card has the same
product equipment code (PEC) and PEC suffix, as the removed card.
At the MAP display
3
To access the PM level and post the RMM, type
>MAPCI;MTC;PM;POST RMM rmm_no
and press the Enter key.
where
rmm_no
is the number of the RMM, the location the card to remove
Example of a MAP display:
RMM
5
SysB
4
To busy the RMM, type
>BSY
and press the Enter key.
Example of a MAP display:
RMM
5
ManB
At the RMM shelf
5
CAUTION
Static discharge can cause damage to circuit packs
Wear a wrist strap and connect the wrist strap to the
frame of the RMM. Connect the wrist strap before
you remove or insert any cards. The wrist strap
protects the RMM against static electricity service
degradation.
RLCM-EDC card replacement procedures 6-43
DMS-100 Family Maintenance Manual ABSK007
NT2X59
in RMM
(continued)