6-40 RLCM-EDC card replacement procedures
NT2X57
NT2X57
in RMM
in RMM
(end)
(continued)
At the MAP terminal
4
5
6
7
8
297-8381-550 Standard 02.02 April 1999
To verify the signal distribution circuits on the removed card, type
>POST P RMM rmm_no ckt_no
and press the Enter key.
where
rmm_no
is the number of the RMM shelf, the location of the replaced card
ckt_no
is the number of the first circuit and the location of the NT2X5 card.
Example of a MAP response:
LAST CIRCUIT = 14
POST CKT IDLED
SHORT CLLI IS:
OK, CLLI POSTED
POST
13
DELQ
TTP 6–006
CKT TYPE
PM NO.
OG TESTEQ RMM 0 0
To send defective cards for repair, follow the local procedures.
Record information for office records, as follows:
date of card replacement
serial number of the card
details or reasons for replacement of the card
Go to step 8.
For additional help, contact the next level of maintenance.
The procedure is complete.