Nortel DMS-100 Series Maintenance Manual page 280

Remote line concentrating module with extended distance capability
Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

6-92 RLCM-EDC card replacement procedures
NT6X52
in LCM
(continued)
Summary of replacing an NT6X52 card in LCM
At PM level of MAP
display, post the
LCM
Busy the unit with
the defective card
Replace card with
one that has
identical PEC
Query the OOS
LCM unit for valid
loadfiles
Is loadfile
valid?
N
Load the LCM unit
Return the busied
LCM unit to service
297-8381-550 Standard 02.02 April 1999
Y
Return LCM unit to
service
RTS pass?
N
This flowchart summarizes the
procedure.
Use the instructions that follow
this flowchart to perform the
procedure.
RTS pass?
N
Y
End of procedure
Contact
maintenance
support group
Y

Advertisement