Troubleshooting Ptx5000 Pic Transceivers - Juniper PTX5000 Hardware Manual

Packet transport router
Hide thumbs Also See for PTX5000:
Table of Contents

Advertisement

Troubleshooting PTX5000 PIC Transceivers

IN THIS SECTION
Problem | 628
Solution | 628
Problem
Description
A problem has occurred with a PIC transceiver.
Solution
To troubleshoot a PIC transceiver:
1. Check the status of the optical transceivers. Issue the show interfaces diagnostics optics command.
Alarms and warnings should be Off.
user@host> show interfaces diagnostics optics
Physical interface: et-0/0/0
Module temperature
Module voltage
Module temperature high alarm
Module temperature low alarm
Module temperature high warning
Module temperature low warning
Module voltage high alarm
Module voltage low alarm
Module voltage high warning
Module voltage low warning
Module not ready alarm
Module low power alarm
Module initialization incomplete alarm
Module fault alarm
PLD Flash initialization fault alarm
Power supply fault alarm
: 39 degrees C / 102 degrees F
: 1.1470 V
: Off
: Off
: Off
: Off
: Off
: Off
: Off
: Off
: Off
: Off
: Off
: Off
: Off
: Off
628

Advertisement

Table of Contents
loading

Table of Contents