Cabling card cage modules to the cross-connect terminal

Each cardcage (NT8D37) module is equipped with a series of connectors
mounted on the I/O panel at the rear of the module that extends the pins from
the peripheral equipment card slots in the module. These I/O connectors are
connected to the cross-connect terminal with NE-A25B type cables.
Figure "IPE input/output panels" on page 4-25 illustrates the left and right I/O
connector panels on the rear of the IPE module. Cables D, H, N, and U are not
used in the standard 12-cable configuration for the backplane in the NT8D37
IPE module. However, those cables are used in the expanded 16-cable
configuration. Figure "NT8D37 backplane cable designations (standard
configuration)" on page 4-26 shows the backplane cable designations for the
12-cable standard configuration. Figure "NT8D37 backplane cable
Meridian SuperNode MSL-100 Intelligent Peripheral Equipment (IPE) Reference Manual MSL14
One (1) lug on stud
Cable and lug
Star washer P097Y579 (2)
Battery return plate
Lock washer P0183028
Hex bolt P0545096
Cabling specifications 4-23
Hex nut P0065747 (3)
Flat washer P0160759
Lock washer P0183028