7-8 Log and fault reports

PM189

Log 189 helps Nortel Networks personnel determine the cause for different
switch events. It is generated when one of the following occurs:
The following is an example report format:
<Office ID>PM189<mmmdd hh:mm:ss ssdd>INFO PM SW Information
ReportIPE <Frame><Shelf><text>
The meaning of the text value can be derived from the following table:
Table 7-2 7-PM189 field descriptions (Sheet 1 of 2)
Text value
Flash boot load update
Flash boot load update failure
Corrupt load transferred
Memory not initialized
DRAM write failure
SRAM write failure
555-4001-129 Standard 08.01 November 2000
an error is detected in the load file during a Switch Manager directed
software upgrade
an error is detected in transferring a software load from Flash memory to
executable memory during the performace of an IPE RTS operation
an attempt to allocate buffer space in DRAM fails
an attempt to allocate buffer space in SRAM fails
an error is detected in programming a software load into Flash memory
during a Switch Manager directed software upgrade
an error is encountered in attempting to change the designated Flash boot
load
when an attempt is made to establish a connection to the IPE through its
Ethernet port
Event description
This log will be generated whenever the
Switch Manager modifies the
designated Flash boot load.
This log will be generated when an error
is encountered in attempting to change
the designated Flash boot load.
This log will be generated when an error
is detected in the load file during a
Switch Manager directed software
upgrade.
This log will be generated when an error
is detected in transferring a software
load from Flash memory to executable
memory during the performance of an
IPE RTS operation.
This log will be generated when an
attempt to write to DRAM fails.
This log will be generated when an
attempt to write/read from SRAM fails.