Rack-mount recommendations

When you mount the chassis in the rack, observe the following recommendations:
The maximum recommended ambient temperature is 40
sure that the internal temperature of the rack does not exceed 40
Do not block the power supply vents or otherwise restrict air flow when
installing the chassis in a rack.
Stabilize your rack so that it does not tip over under the weight of the gateway
and other devices.
Warning: The Contivity 5000 weighs approximately 50 pounds (23 kg).
This weight is not evenly distributed; the right side of the gateway
weighs more than the left. Two people must lift the system into the
equipment rack.
Make sure that the electrical branch circuits can handle the Contivity 5000
and other units in the rack before you install and turn on the system.
Maintain a reliable earth-ground path in the rack system. The gateway is
intended to connect to an earth ground.

Attaching the shelf in the equipment rack

The Contivity 5000 ships with a rack-mount shelf to support the chassis in the
equipment rack. To attach the shelf to the equipment rack:
1
If the holes in the rack's vertical supports are not threaded, attach a cage nut in
four locations at the front of the rack

Figure 3 Attaching the cage nuts to the rack

Rail
without
threaded
holes
Cage nut
Chapter 1 Installing the Contivity 5000 chassis 27
(Figure
CS260003A
o
C (104
o
F). Make
o
C (104
3).