[8PWR] Sensors Plugin

Sensors 1-Wire
Sensors 1-Wire (
Temperature 1-wire, (THS), 2m
extension cords or splitters. Maximum cable length 1-Wire network is limited to 50 meters.
Sensors of Dry Contact Type
Dry contact sensors are door opening sensors, buttons and other sensors, with a mechanism of work based on opening/closing a conductor. A
sensor is connected with two wires to an IO line of a device according to the table (an order of plugging wires does not matter).
Sensor Flex
NetPing 8/PWR-220 v4/SMS Terminal
First wire
One of IO lines – 1/2/3/4
Second wire
Important! Sensors of a dry contact type, a
can plug any four sensors out of this set.
Important! A corresponding IO line should be set to an input mode in settings of a device.
A sensor is packaged with an inseparable cable, with connectors on the ends. A cable length can be increased with the help of
extenders of RC-4
sensor, which are sequentially plugged one into another. Or it can be done independently with the help of any wire with a
minimum cross section of 0,4 mm . Maximum allowable length of a flat cable is 100 m.
Leakage Sensors
A leakage sensor is connected by a four-wire line according to the table.
Sensor Flex
NetPing 8/PWR-220 v4/SMS Terminal
Green
One of IO lines – 1/2/3/4
Yellow (White)
Red
Black
Important! Sensors of a dry contact type, a
can plug any four sensors out of this set.
Important! A corresponding IO line should be set to an input mode in settings of a device.
A sensor is packaged with an inseparable cable, with connectors on the ends. A cable length can be increased with the help of
extenders of RC-4
sensor, which are sequentially plugged one into another. Or it can be done independently with the help of any wire with a
minimum cross section of 0,4 mm . Maximum allowable length of a flat cable is 100 m.
Supply Voltage Sensor
supply voltage sensor
is plugged by a two-wire line according to the table. 
Sensor Flex
NetPing 8/PWR-220 v4/SMS Terminal
First wire
One of IO lines – 1/2/3/4
Second wire
Copyright © NetPing east Co., Ltd / E-mail:
 and 
Humidity sensor 1-wire
G
supply voltage sensor
2
G
+
G
supply voltage sensor
2
G
support@netpingdevice.com www.netpingdevice.com
) connected to the connectors 1W plugs RJ12, allowed to use
, a leakage sensor, and others are plugged to IO lines of a device. You
, a leakage sensor, and others are plugged to IO lines of a device. You
An order of plugging wires does not matter.
/
/ Phone: +886-2-23121582