PaloAlto Networks PA-5400 Series Hardware Reference Manual page 107

Next-gen firewall
Hide thumbs Also See for PA-5400 Series:
Table of Contents

Advertisement

Service the PA-5400 Series Firewall Hardware
partition shows the status clean, degraded, and drive Sys1 is missing from the panlogs
array; together, these indicate that you need to replace the Sys1 drive.
admin@PA-5420> show system raid detail
Overall System Drives RAID status
-----------------------------------------------------------------------------
Drive status
Disk id Sys1
(MICRON_M510DC_MT)
Disk id Sys2
(MICRON_M510DC_MT)
-----------------------------------------------------------------------------
Partition status
panlogs
Drive id Sys2
maint
Drive id Sys1
Drive id Sys2
sysroot0
Drive id Sys1
Drive id Sys2
sysroot1
Drive id Sys1
Drive id Sys2
pancfg
Drive id Sys1
Drive id Sys2
panrepo
Drive id Sys1
Drive id Sys2
swap
Drive id Sys1
Drive id Sys2
STEP 2 |
Remove the failed drive from the RAID 1 array. In this example, run the following command
to remove drive Sys1 from the array:
admin@PA-5420> request system raid remove sys1
STEP 3 |
Confirm that the failed drive is removed from all partitions. In the following output of the
show system raid detail, you see that drive id Sys1 is now missing from all
partitions.
admin@PA-5420> show system raid detail
Overall System Drives RAID status
-----------------------------------------------------------------------------
Drive status
Disk id Sys1
(MICRON_M510DC_MT)
PA-5400 Series Next-Gen Firewall Hardware Reference
degraded
Present
Present
clean, degraded
active sync
clean
active sync
active sync
clean
active sync
active sync
clean
active sync
active sync
clean
active sync
active sync
clean
active sync
active sync
clean
active sync
active sync
degraded
Present
107