7.4 MODBUS MEMORY MAP
Table 7–5: 745 MEMORY MAP (Sheet 20 of 35)
GROUP
ADDR
(HEX)
VIRTUAL
1407
INPUTS
1410
continued
1411
141A
141B
1424
1425
142E
142F
1438
1439
1442
1443
144C
144D
1456
1457
1460
1461
1462
1463
1464
1465
1466
1467
1468
1469
146A
146B
146C
146D
146E
146F
1470
7
↓
147F
OUTPUT
1480
RELAY 1
1489
148A
148B
149F
↓
14AF
OUTPUT
14B0
RELAY 2
14B9
14BA
14BB
14CF
↓
14DF
OUTPUT
14E0
RELAY 3
14E9
14EA
14EB
7-32
Courtesy of NationalSwitchgear.com
DESCRIPTION
Virtual Input 8 Name (9 registers)
Virtual Input 9 Function
Virtual Input 9 Name (9 registers)
Virtual Input 10 Function
Virtual Input 10 Name (9 registers)
Virtual Input 11 Function
Virtual Input 11 Name (9 registers)
Virtual Input 12 Function
Virtual Input 12 Name (9 registers)
Virtual Input 13 Function
Virtual Input 13 Name (9 registers)
Virtual Input 14 Function
Virtual Input 14 Name (9 registers)
Virtual Input 15 Function
Virtual Input 15 Name (9 registers)
Virtual Input 16 Function
Virtual Input 16 Name (9 registers)
Virtual Input 1 Target
Virtual Input 2 Target
Virtual Input 3 Target
Virtual Input 4 Target
Virtual Input 5 Target
Virtual Input 6 Target
Virtual Input 7 Target
Virtual Input 8 Target
Virtual Input 9 Target
Virtual Input 10 Target
Virtual Input 11 Target
Virtual Input 12 Target
Virtual Input 13 Target
Virtual Input 14 Target
Virtual Input 15 Target
Virtual Input 16 Target
Reserved
↓
Reserved
Output 1 Name (9 registers)
Output 1 Operation
Output 1 Type
Output 1 FlexLogic (20 registers)
Reserved
↓
Reserved
Output 2 Name (9 registers)
Output 2 Operation
Output 2 Type
Output 2 FlexLogic (20 registers)
Reserved
↓
Reserved
Output 3 Name (9 registers)
Output 3 Operation
Output 3 Type
Output 3 FlexLogic (20 registers)
745 Transformer Management Relay
RANGE
STEP
UNITS
VALUE
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
↓
↓
↓
---
---
---
---
---
---
---
---
---
---
---
---
↓
↓
↓
---
---
---
---
---
---
---
---
---
---
---
---
↓
↓
↓
---
---
---
---
---
---
---
---
---
---
---
---
7 COMMUNICATIONS
FORMAT
FACTORY
CODE
DEFAULT
F33
"Virtual Input 8"
F30
0 = Disabled
F33
"Virtual Input 9"
F30
0 = Disabled
F33
"Virtual Input 10"
F30
0 = Disabled
F33
"Virtual Input 11"
F30
0 = Disabled
F33
"Virtual Input 12"
F30
0 = Disabled
F33
"Virtual Input 13"
F30
0 = Disabled
F33
"Virtual Input 14"
F30
0 = Disabled
F33
"Virtual Input 15"
F30
0 = Disabled
F33
"Virtual Input 16"
F46
0 = Self-Reset
F46
0 = Self-Reset
F46
0 = Self-Reset
F46
0 = Self-Reset
F46
0 = Self-Reset
F46
0 = Self-Reset
F46
0 = Self-Reset
F46
0 = Self-Reset
F46
0 = Self-Reset
F46
0 = Self-Reset
F46
0 = Self-Reset
F46
0 = Self-Reset
F46
0 = Self-Reset
F46
0 = Self-Reset
F46
0 = Self-Reset
F46
0 = Self-Reset
↓
↓
F33
Solid State Trip
F66
0 = self-resetting
F38
0 = Trip
F47
---
↓
↓
F33
"Trip 1"
F66
0 = self-resetting
F38
0 = Trip
F47
---
↓
↓
F33
"Trip 2"
F66
0 = self-resetting
F38
0 = Trip
F47
---
GE Multilin