Resetting alarms
There are two types of alarms:
1) ALARMS WITH LATCH
To reset an alarm with latch, go to the ALARM page that shows details of the alarm to be reset and press the ACK key:
- if the cause of the error is no longer active, the corresponding message is deleted from the alarms list
- if the cause of the error is still active, the corresponding message remains on the alarms list
2) ALARMS WITHOUT LATCH
These are automatically reset when the cause of the error is removed. The ALM Led and the ALARM page are automatically updated.
Alarm list
ALARMS WITH LATCH
AL1
AL2
AL3
AL4
ALHB_1
ALHB_2
ALHB_3
SCR_SHORT_1
SCR_SHORT_1_2 (*)
SCR_SHORT_1_3 (*)
NO_VOLTAGE_1
NO_VOLTAGE_1_2 (*)
NO_VOLTAGE_1_3 (*)
NO_CURRENT_1
NO_CURRENT_1_2 (*)
NO_CURRENT_1_3 (*)
SCR_SHORT_2
NO_VOLTAGE_2
NO_CURRENT_2
SCR_SHORT_3
NO_VOLTAGE_3
NO_CURRENT_3
(*) for 3-phase configuration only
ALARMS WITHOUT LATCH
MODE_ERROR
ROTATION123_ERROR
UNBALANCED30_ERROR
ANGLE_ERROR
SENSOR_OVER_HEAT_1
SENSOR_BROKEN_1
SHORT_CIRCUIT_CURRENT_1
ALPOWER_1
HWOVERHEAT_1
FUSE_OPEN_1
SENSOR_OVER_HEAT_2
SENSOR_BROKEN_2
SHORT_CIRCUIT_CURRENT_2
ALPOWER_2
HWOVERHEAT_2
FUSE_OPEN_2
SENSOR_OVER_HEAT_3
SENSOR_BROKEN_3
SHORT_CIRCUIT_CURRENT_3
ALPOWER_3
HWOVERHEAT_3
FUSE_OPEN_3
92
VARIABLE
BIT
STATUS1
8
STATUS1
9
STATUS1
10
STATUS1
11
STATUS1
12
STATUS1
13
STATUS1
14
STATUS3
3
STATUS3
4
STATUS3
5
STATUS3
6
STATUS3
7
STATUS3
8
STATUS3
9
STATUS3
10
STATUS3
11
STATUS3
3
STATUS3
6
STATUS3
9
STATUS3
3
STATUS3
6
STATUS3
9
VARIABLE
BIT
MODE_STATUS
8
VOLTAGE_STATUS
4
VOLTAGE_STATUS
3
VOLTAGE_STATUS
5
STATUS4
1
STATUS4
0
STATUS4
6
STATUS4
9
STATUS4
14
STATUS4
10
STATUS4
1
STATUS4
0
STATUS4
6
STATUS4
9
STATUS4
14
STATUS4
10
STATUS4
1
STATUS4
0
STATUS4
6
STATUS4
9
STATUS4
14
STATUS4
10
ZONE
GLOBALE
ALARM 1
GLOBALE
ALARM 2
GLOBALE
ALARM 3
GLOBALE
ALARM 4
GLOBALE
ALARM HEATER BREAK IN GFW-M
GLOBALE
ALARM HEATER BREAK IN GFW-E1
GLOBALE
ALARM HEATER BREAK IN GFW-E2
GFW-M
ALARM SCR SHORT
GFW-M
ALARM SCR SHORT IN GFW-E1
GFW-M
ALARM SCR SHORT IN GFW-E2
GFW-M
ALARM NO VOLTAGE
GFW-M
ALARM NO VOLTAGE IN GFW-E1
GFW-M
ALARM NO VOLTAGE IN GFW-E2
GFW-M
ALARM NO CURRENT
GFW-M
ALARM NO CURRENT IN GFW-E1
GFW-M
ALARM NO CURRENT IN GFW-E2
GFW-E1
ALARM SCR SHORT
GFW-E1
ALARM NO VOLTAGE
GFW-E1
ALARM NO CURRENT
GFW-E2
ALARM SCR SHORT
GFW-E2
ALARM NO VOLTAGE
GFW-E2
ALARM NO CURRENT
ZONE
GLOBALE
DIP-SWITCHES CONFIG NOT VALID
GLOBALE
PHASES ROTATION ERROR
GLOBALE
30% UNBALANCED LINE
GLOBALE
THREE PHASE MISSING LINE
GFW-M
TEMPERATURE SENSOR OVER HEAT
GFW-M
TEMPERATURE SENSOR BROKEN
GFW-M
SHORT CIRCUIT CURRENT DURING SOFTSTART
GFW-M
24V FAN PRESENCE
GFW-M
SSR HARDWARE OVER TEMPERATURE
GFW-M
FUSE OPEN
GFW-E1
TEMPERATURE SENSOR OVER HEAT
GFW-E1
TEMPERATURE SENSOR BROKEN
GFW-E1
SHORT CIRCUIT CURRENT DURING SOFTSTART
GFW-E1
24V FAN PRESENCE
GFW-E1
SSR HARDWARE OVER TEMPERATURE
GFW-E1
FUSE OPEN
GFW-E2
TEMPERATURE SENSOR OVER HEAT
GFW-E2
TEMPERATURE SENSOR BROKEN
GFW-E2
SHORT CIRCUIT CURRENT DURING SOFTSTART
GFW-E2
24V FAN PRESENCE
GFW-E2
SSR HARDWARE OVER TEMPERATURE
GFW-E2
FUSE OPEN