120
121
197
Ld.st
619
Ld.2
620
Ld.3
621
Ld.4
622
Ld.s
623
Ld.6
624
Ld.7
625
Ld.8
LED status refers to the corresponding parameter, with the following special cases:
- LED RN (green) on: hotkey functionality
- LED RN (green) + LED ER (red) both flashing rapidly: autobaud in progress
- LED ER (red) flashing: temperature alarm ((OVER_HEAT or TEMPERATURE_SENSOR_BROKEN) or alarm of SHORT_CIRCUIT_CURRENT or SSR_SAFETY or
FUSE_OPEN (only for singlephase configuration).
- LED ER (red) + LED Ox (yellow) both flashing: HB alarm or POWER_FAIL in zone x
- All LEDs flashing rapidly: ROTATION123 alarm (only for threephase configuration)
- All LEDs flashing rapidly except LED DI1: jumper configuration not provided
- All LEDs flashing rapidly except LED DI2: 30%_UNBALANCED_ERROR alarm (only for threephase configuration)
- All LEDs flashing rapidly except LED O1: SHORT_CIRCUIT_CURRENT alarm (only for threephase configuration)
- All LEDs flashing rapidly except LED O2: TRIPHASE_MISSING_LINE_ERROR alarm (only for threephase configuration)
- All LEDs flashing rapidly except LED O3: SSR_SAFETY alarm (only for threephase configuration)
- All LEDs flashing rapidly except LED BUT: FUSE_OPEN alarm (only for threephase configuration)
305*
68
ON
ON
OFF
ON
OFF
ON
OFF
R
Manufact - Trade Mark (Gefran)
R
Device ID (GFW600A)
R/W
RN LED status function
R/W
ER LED status function
R/W
Function of LED DI1
R/W
Function of LED DI2
R/W
Function of LED O1
R/W
Function of LED O2
R/W
Function of LED O3
R/W
Function of LED BUTTON
R/W
Current state (STATUS_W)
ON
ON
OFF
3-phase load closed delta
OFF
ON
3-phase star load without neutral
OFF
OFF
3-phase star load without neutral with BIFASE control
OFF
OFF
3-phase closed star load with BIFASE control
Val
Function
0
RUN
1
MAN/AUTO controller
6
Repeat digital input INDIG1
7
Serial 1 dialog
8
State of OUT 2 zone 1
11
Repeat digital input INDIG2
12
None fonction
13
Serial 2 dialog
14
Repeat digital input INDIG3
15
Repeat digital input INDIG4
+16
LED flashing if active (code 8 excluded)
0
Disabled
1
Repetition of state OUT 1
2
Repetition of state OUT 2
3
Repetition of state OUT 3
4
State key
5
Repetition of state OUT 5
6
Repetition of state OUT 6
7
Repetition of state OUT 7
8
Repetition of state OUT 8
9
Repetition of state OUT 9
10
Repetition of state OUT 10
12
Serial 1 dialog
13
Serial 2 dialog
14
Repeat digital input INDIG3
15
Repeat digital input INDIG4
+16
LED flashing if active
Table of state settings
bit
3
Selct ON/OFF
4
Select AUTO/MAN
Name of manufacturer
Product ID
Table of LED functions
Table of OUT LED functions
0
zone1
80997D_MSW_GFW_400-600_04-2021_ENG
5000
218
16
12
6
11
1
2
3
4
0
0
zone2
zone3