Maximum conduction value in this phase can be limited by means of the PS.Hi parameter.
If requested, MUST be activated only with Hd.6=0 (the required Hd.6 value can be set only after calibration).
In case of HSC firng mode, the Heater Break alarm teach-in function doesn't calibrate at 5%, 3%, 2% and 1% in order to avoid high peak
currents due to the low impedence at very low temperature of the IR lamp filament.
Enable alarm
195*
R/W
AL.n
57*
R/W
Xb.f
56*
R/W
XB.T
Calibration HB
112*
R/W
alarm setpoint
bit
for zone
Alarm setpoints
55*
R/W
A.xb1
502
R/W
A.xb2
503
R/W
A.xb3
737*
R/W
xb.P
742*
R/W
xb.tA
452*
R/W
xb.t
743*
R/W
xb.P W
758*
R/W
Ir.tA.0
80997D_MSW_GFW_400-600_04-2021_ENG
Select number of enabled
alarms
HB alarm functions
Delay time for activation
of HB alarm
OFF = Calibration not enabled
ON = Calibration enabled
HB alarm setpoint (scale points
ammeter input - Phase 1)
HB alarm setpoint (scale points
ammeter input - Phase 2)
HB alarm setpoint (scale points
ammeter input - Phase 3)
Percentage HB alarm setpoint
of current read in HB
calibration
CT read in HB calibration
TV read in HB calibration
Ou.P power in calibration
HB Calibration with IR lamp:
current at 100% conduction
See: Table of enable alarms
Table of HB alarm functions
Description of functions
Val
Relay, logic output: alarm active at a
0
load current value below set point for
control output ON time.
Relay, logic output: alarm active at a
1
load current value above set point for
control output OFF time.
Alarm active if one of functions 0 and 1
2
is active (OR logic between functions
0 and 1) (*)
3
Continuous heating alarm
7
Continuous cooling alarm
Default:
SINGLE-PHASE LOAD: each A.HbX refers to
its respective phase
3-PHASE LOAD: single reference setpoint
A.Hb1 and OR among phases 1, 2 and 3.
+ 8 HB reverse alarm
+ 16 relates to single setpoints and singled
phases WITH 3-PHASE LOAD
+32 HB alarm with memory
The value must exceed
the cycle time of the
0 ... 999 sec.
output to which the HB
alarm is associated.
NB: In case of 3-phase load, you can set a different value for parame-
ter A.Hb1, A.Hb2, A.Hb3 for each zone (ex.: to control an unbalanced
3-phase load)
0.0...3275.0 A
0.0...3275.0 A
With 3-phase load
0.0...3275.0 A
With 3-phase load
0.0...100.0 %
0.0...3275.0 A
0.0...999.9 V
0.0...100.0 %
0.0...3275.0 A
3
3
3
Zone 1
Zone 2
Zone 3
0
0
0
Zone 1
Zone 2
Zone 3
5
5
5
Zone 1
Zone 2
Zone 3
10.0
10.0
10.0
Zone 1
Zone 2
Zone 3
10.0
10.0
80.0
80.0
80.0
Zone 1
Zone 2
Zone 3
0.0
0.0
0.0
Zone 1
Zone 2
Zone 3
0.0
0.0
0.0
Zone 1
Zone 2
Zone 3
0.0
0.0
0.0
Zone 1
Zone 2
Zone 3
0.0
0.0
0.0
Zone 1
Zone 2
Zone 3
35

Advertisement

Table of Contents
loading

Table of Contents