Enter Setup
Continuous Mode
If the Continuous mode is enabled, the scanner automatically starts one decode session after another. To
suspend/resume barcode reading, simply press the trigger.
Continuous Mode
Decode Session Timeout
This parameter sets the maximum time decode session continues during a scan attempt. It is
programmable in 1ms increments from 100ms to 3,600,000ms. The default setting is 3,000ms. To learn
how to program this parameter, see Appendix 5.
Decode Session Timeout
Timeout between Decodes
This parameter sets the timeout between decode sessions. When a decode session ends, next session
will not happen until the timeout between decodes expires. It is programmable in 1ms increments from 0ms
to 65,535ms. The default setting is 1,000ms. To learn how to program this parameter, see Appendix 5.
Timeout between Decodes
** Exit Setup