Introduction; Commands; Command Single Parameter - gefran POS-MINI SIEIDrive Instruction Manual

One-axis positioner
Table of Contents

Advertisement

This manual describes the functioning methods, the configuration and the use of an independent positioner.
This positioner is suitable for DGFC mounted on AVy drives with a 1.xxx firmware version, on TPD32 from
8.000 firmware version and on AMV32 from 4.100 firmware version.
The positioner control unit supplies the following commands:
Zero cycle.
Jog+ and Jog- movements.
Jog movements with a fixed delta space
Movement to Set Point 1.
Movement to Set Point 2
Movement to a 63-set point array.
The commands can be sent to the control unit with three different methods:
1. Via some suitaby configured digital inputs.
2. Via boolean parameters, which are specific for each command; such parameters can be written via the
serial communication channels.
3. Via a single parameter where each bit is assigned to a specific command. This parameter can be written
via the serial communication channels.

1.1. COMMAND SINGLE PARAMETER

The command single parameter:
name: dInAs1
has the following structure:
bit
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
One-axis positioner

INTRODUCTION

1. COMMANDS

ipa: 1270
Name
Description
Enable
Positioner enabling
Hold
Hold
ResAlarm
Alarm reset
ZeroSearch
Zero cycle start
Jog+
Jog+ movement
Jog-
Jog- movement
Move1
Movement to Set Point 1
MoveN
Movement to a 63-set point array
IncrJog+
Jog+ movement with a fixed delta space
IncrJog-
Jog - movement with a fixed delta space
Move2
Movement to Set Point 2
Reserved
Reserved
Reserved
ResetOverride
Override set at 100%
EnRampS
S-shaped ramp enabling
—————— Instruction manual ——————
7