5.1.3.10. Detection of the Electronic Limit Switches

Place the axis on the minimum electronic limit switch.
Write in the Minimum parameter the ideal value detected in this point.
Place the axis on the maximum electronic limit switch.
Write in the Maximum parameter the ideal value detected in this point.
Take the DGFC card to the IDLE status
Save the parameters in Flash.
Take the DGFC card first to the READY status and afterwards to the RUN status.
Positive direction
Mechanical
Minimum
Track
-250.34
lower
limit
Lower limit switch
Software lower limit switch

5.1.3.11. Zero Cycle repetition

Every time the card reaches the IDLE status, the system loses the initialization of the zero cycle. Therefore,
after passing through this status, the zero cycle sequence has to be repeated.
Send the StartCycle0 command.
Check that the zero cycle has been completed in the right way.

5.1.3.12. Check of the Electronic Limit Switches

Set the JOG speed equal to 10% of the axis maximum speed.
Send the JOG+ command .
Check that, by pressing the JOG+ button, the axis stops automatically on the max. electronic limit
switch.
Send the JOG- command.
Check that by pressing the JOG- button, the axis stops automatically on the min. electronic limit switch.

5.1.3.13. Calibration of the ideal value

This operation is aimed at setting the ideal value as compared to the axis position. We can therefore imagine
that during this configuration phase the axis is configured as follows:
Positive direction
+
Mechanical
Minimum
track lower
-250.34
limit
Lower limit switch
Software lower limit switch
-250
30
+
Preset = 0
Baseori = 0
Mechanical reference
-100
0
200
400
—————— Instruction manual ——————
GEFRAN
600
800
1000
Track
Maximum
upper
+1399.66
limit
Upper limit switch
Software upper limit switch
Mechanical
Maximum
track upper
+1399.66
limit
Upper limit switch
Software upper limit switch
1400 AXIS quota