Byte 2
PositionStatusByte
.
Byte 3
ReadyByte
Byte 4
ErrorCodeLowByte
Byte 5
ErrorCodeHighByte
Byte 6
ActualPositionLowByte
Byte 7
ActualPositionHighByte
One-axis positioner
dOutAs1:1274 0
Area Change Point 1
1
Area Change Point 2
2
Area Change Point 3
3
Area Change Point 4
4
Move OK = 1
5
Not Moving = 1
6
Moving = 1
7
0
Ready (Axis OK = 1)
1
CYCLE ZERO Enabled = 1
2
Target In 1
3
Target In 2
4
5
Ring Position closed
6
Limit Switch MIN = 1
7
Limit Switch MAX = 1
0
Error Code
1
Error Code
2
Error Code
3
Error Code
4
Error Code
5
Error Code
6
Error Code
7
Error Code
0
Error Code
1
Error Code
2
Error Code
3
Error Code
4
Error Code
5
Error Code
6
Error Code
7
Error Code
dOutAs4:1277 0
Actual Position (Integer)
1
Actual Position (Integer)
2
Actual Position (Integer)
3
Actual Position (Integer)
4
Actual Position (Integer)
5
Actual Position (Integer)
6
Actual Position (Integer)
7
Actual Position (Integer)
0
Actual Position (Integer)
1
Actual Position (Integer)
2
Actual Position (Integer)
3
Actual Position (Integer)
4
Actual Position (Integer)
5
Actual Position (Integer)
6
Actual Position (Integer)
7
Actual Position (Integer)
—————— Instruction manual ——————
Working area output
Value= 1 when the ideal value
corresponds to the active set point value
Value=1 when the axis is stopped
Value=1 when the axis is moving
Vaue=1 when the zero cycle has been
performed.
Value=1 when the real value corre-
sponds to the Target 1 value
Value=1 when the real value corresponds
to the Target 2 value
Value=1 with a closed position loop
Value=1 when the axis is lower or equal
to the minimum limit switch
Value=1 when the axis is higher or equal
to the maximum limit switch
Drive error code
Positioner present value