Nortel Business Communications Manager 450 Installation Manual page 120

Hide thumbs Also See for Business Communications Manager 450:
Table of Contents

Advertisement

120 LED indicators reference
Figure 24 DTM LEDs
Power LED
Status LED
In service LED
Loopback test LED
Receive LEDs
Transmit LEDs
For information about the possible DTM LED states, see
(page
Table 10 DTM LEDs (1 of 2)
Power
Status
Power
Status
In service
Flashing
Loopback test
On
Receive alarm
On
Receive error
On
Copyright © 2006-2009 Nortel Networks
120).
Nortel Business Communications Manager 450 1.0
Installation — System
NN40160-301 01.04 Standard
July 2009
Table 10 DTM LEDs
Description
See
Media bay module LEDs
(page 118)
for details.
See
Media bay module LEDs
(page 118)
for details.
The T1, ETSI, or PRI trunks are out of
service because a loopback test is
running or the DTM is initializing.
A continuity loopback test is running.
A problem with the received digital
transmission. This half-duplex link
does not work.
A small error as a result of degraded
digital transmission. Possible causes
are an ohmic connection, water
ingress, or too long a loop.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Bcm450

Table of Contents