CHAPTER 2 USING THE MACHINE
3.19.7 AGING Test (5: AGING TEST)
A press on '5' on the TEST MODE menu selects the AGING test. In this test, the contact
sensor is turned on, and the original feeder motor of the ADF is driven as it is in Fine mode.
The printer, on the other hand, prints a pattern of diagonal bands in Fine mode.
To end the AGING test, press the Stop key.

3.19.8 FACULTY (function) Test (6: FACULTY TEST)

A press on '6' on the keypad from the TEST MODE menu selects the FACULTY test. A
press on the keypad (1 through 7, 9, #) during the test will bring up the following menu:
Keypad
Keypad
1
1
G3 Signal Transmission Test
G3 Signal Transmission Test
2
2
not used
not used
3
3
Sensor Test
Sensor Test
4
4
????
????
5
5
not used
not used
6
6
????
????
7
7
Control Panel Test
Control Panel Test
9
9
Live Connection Reception Test
Live Connection Reception Test
#
#
ESS Test
ESS Test
G3 Signal Transmission Test (6-1: G3 4800 bps Tx)
A press on '1' on the keypad on the FACULTY TEST selects the G3 transmission test. In
this test, a G3 signal is transmitted using the telephone line terminal and the speaker at 4800
bps.
Sensor Test (6-3: SENSOR)
This mode is used to check the state of a specific sensor of the machine on the display. A
press on '3' on the keypad from the FACULTY TEST mode selects the sensor test. The dis-
play indication changes as the senor goes ON and OFF.
2-68
COPYRIGHT © 2001 CANON INC.
Chapter2.p65
Item
Item
Transmits a G3 signal at 4800 bps to the telephone
Transmits a G3 signal at 4800 bps to the telephone
lien and the speaker.
lien and the speaker.
Executes an operation test on a specific sensor.
Executes an operation test on a specific sensor.
Executes an operation test on the ADF.
Executes an operation test on the ADF.
-
-
Executes an operation test on the speaker.
Executes an operation test on the speaker.
Executes an operation test on the control panel keys.
Executes an operation test on the control panel keys.
Executes an operation test on the signal sensor on
Executes an operation test on the signal sensor on
the NCU board and the frequency counter.
the NCU board and the frequency counter.
Executes an operation test on the ESS (energy save)
Executes an operation test on the ESS (energy save)
function.
function.
CANON imageCLASS D600s/PC1060s/PC1200s/iR1200s REV. 0 SEPT. 2001