COMMISSIONING
GAS PRESSURES
RHFE0800SF/DF
Gas Type
S-F
Gas rate Hi
35
Gas rate Lo
LH RH injector Ø
Aeration sleeve LH RH
Pilot
PL
PH
0.95 0.79 1.70 1.35
RHFE1000S/D
Gas Type
S-F
Gas rate Hi
34
Gas rate Lo
LH RH injector Ø
Aeration sleeve LH RH
Pilot
PL
PH
0.80 0.65 1.85 1.57
SETTING GAS PRESSURES
The sequence will vary slightly depending on the model:
Linear 800, 1000:
IMPORTANT
Linear 1500:
Checking the Supply Pressure
1.
Remove the inlet test point screw and connect the manometer hose.
2.
Press the heater 'ON/OFF' button to start the ignition sequence, ensuring the correct inlet pressure is available
with all other gas appliances operating on high.
3.
Press the heater 'ON/OFF' button to stop the heater operation.
4.
Disconnect the manometer hose and replace the inlet test point screw.
Rinnai
Natural
Propane
L-F
S-F
L-F
32
35
32
15
15
2.0
1.30
4.5 x 1
9 x 2
0.98
2.0
0.20
0.25
Natural
Propane
L-F
S-F
L-F
31
32
29
15
14
2.8
1.7
22
0
0.98
2.0
0.19
0.40
PL > PH
PL > PF > PA > PH
Gas Type
Unit
Gas rate Hi
MJ/hr
Gas rate Lo
Main injector Ø
mm
LH RH injector Ø
Aeration sleeve centre
kPa
Aeration sleeve LH RH
Pilot
PL
PF
PA
Unit
PH
MJ/hr
mm
S-F = Short Flue Setting
L-F = Long Flue Setting
LH = Left Hand
kPa
RH = Right Hand
24
RHFE1500S/D
Natural
Propane
S-F
L-F
S-F
L-F
40
37
40
37
14
14
2.3
1.4
1.6
0.95
22.5
N/A
21
17
0.98
2.0
0.3
1.0
0.87
2.0
0.59
1.0
0.80 0.67 1.90 1.54
PL = Main burner on Low
PF = Main burner on High
PA = All burners on Low
PH = All burners on High
RHFE0800F_1000_1500 IM
Unit
MJ/hr
mm
kPa