Commissioning; General Information; Gas Pressure Setting - Rinnai Flametech LS1000 Installation Manual

Ls - gas fireplace
Hide thumbs Also See for Flametech LS1000:
Table of Contents

Advertisement

COMMISSIONING

GENERAL INFORMATION

Accessing the commissioning instructions installed in the bottom of the unit will not normally
occur during installation, which is why the instructions are detailed in this section of the manual.
NOTE
For servicing and maintenance purposes the commissioning instructions are also included in the
service manual. The location of the commissioning instruction pouch within the appliance is as
follows:
RHFE1500 - Located to the right hand side of the gas control
RHFE0800F/1000 - Located tucked in behind the Wi-Fi module
When performing the commissioning, the appliance electrical power will need to be connected.
Exercise CAUTION as there is potential for electric shock from the exposed wiring and circuitry.
DO NOT leave the appliance unattended when power is connected and the panels are removed.
WARNING
Installation and commissioning must be carried out by an Authorised person.
Wiring inside this appliance may be at 240V potential.
DO NOT test for gas escapes with an open flame.
LS - Gas Fireplace heaters have two dipswitch settings for flue length.
L - F (Long Flue) this is the factory set default and in general will not require alteration.
IMPORTANT
S - F (Short Flue) refer to service manual or contact Rinnai for further details.
During commissioning the plastic push buttons on the PCB are required to be pressed to make
adjustments. DO NOT use mechanical items such as screwdrivers to depress these button as
this may lead to breakage.

GAS PRESSURE SETTING

The LS - Gas Fireplace heaters come with the high and low operating pressures factory pre-set.
Gas Supply and Burner pressures MUST BE checked during installation and prior to the
IMPORTANT
installation of the burn media. This is to be done with the glass off and before the burn media* 
is added. Make adjustments if the unit is not operating correctly after all other possible other
causes have been eliminated.
Inlet supply pressure to the appliance MUST be checked and set within the operating parameters
of the appliance in all instances. If the appliance cannot be adjusted to perform correctly contact
Rinnai for advice.
Confirm gas type: this appliance available in either Natural or Propane gas, check labelling on top 
panel to verify gas type. Contact local gas authority to confirm gas supply type if you are in doubt.
*  For  heaters  fitted  with  the  Flametech
logs supplied with the burn media are also the main burners for these appliances. As such it is
necessary to temporarily install these logs onto the aeration sleeves during commissioning.
The pressures can be checked by operating the buttons on the control panel
PCB through the front access panels of the heater before the wall lining has
been installed, or by pulling out the control panel PCB and accessing the
buttons through the opening from the front of the appliance as shown right.
Check the pressures against those printed on the data plate of the appliance.
If the data plate is not easily accessible the pressures are also detailed
on the next page. Even if no adjustment of the gas pressures is required,
access to the 'SET' button may be required to proceed to the next setting.
Rinnai
burner media (models RHFE0800SF/DF), the two large
®
22
RHFE0800F_1000_1500 IM

Advertisement

Table of Contents
loading

This manual is also suitable for:

Flametech ls1500Rhfe0800fRhfe1000Rhfe1500

Table of Contents