FLUEING

FLUE TERMINAL LOCATION

Ensure that the location of the flue terminal can comply with the requirements of AS/NZS 5601 -
Fig. 6.2 which is reproduced in part below.
WARNING
AS/NZ 5601 was current at the time of printing but may have been superseded. It is the installer's
responsibility to ensure that requirements of the current version of AS/NZS 5601 are met.
Refer to separately supplied Rinnai LS - Gas Fireplace - Flue Installation Manual for comprehensive
flue installation details.
g
T
S
LEGEN D:
I
= M e c hani c al air inl et
M = G a s m eter
P = El e c tr i c it y m eter or fu se b ox
S = S tr u c ture
R
. f e
Below eaves, balconies and other projections:
a
• Appliances up to 50 MJ/h input
• Appliances over 50 MJ/h input
b
F
o r
m
t
e h
r g
u o
d n
a ,
o b
e v
a
a b
o c l
y n
c
r F
n o
a t
e r
u t
n r
w
l l a
r o
x e
r e t
a n
c l
r o
e n
From a gas meter (M) (see 5.11.5.9 for vent terminal location of regulator )
d
(see Table 6.6 for New Zealand requirements)
e
From an electricity meter or fuse box (P) †
f
F
o r
m
a
d
a r
n i
i p
e p
r o
i o s
i p l
e p
Horizontally from any building structure* = or obstruction facing a terminal
g
From any other flue terminal , cowl, or combustion air intake †
h
Horizontally from an openable window, door, non-mechanical air inlet, or any other opening into a
building with the exception of sub-floor ventilation:
• Appliances up to 150 MJ/h input *
• Appliances over 150 MJ/h input up to 200 MJ/h input *
j
• Appliances over 200 MJ/h input up to 250 MJ/h input *
• Appliances over 250 MJ/h input *
• All fan-assisted flue appliances , in the direction of discharge
k
F
o r
m
a
m
c e
a h
i n
l a c
r i a
l n i
, t e
n i
u l c
i d
Vertically below an openable window, non-mechanical air inlet, or any other opening into a
building with the exception of sub-floor ventilation:
S
a p
e c
h
a e
e t
s r
p u
o t
0 5
M
J
h /
i r
p n
n
• Other appliances up to 50 MJ/hr input
• Appliances over 50 MJ/h input and up to 150 MJ/h input
• Appliances over 150 MJ/h input
The flue terminal should be positioned away flammable materials.
WARNING
Rinnai
O p ening into
a b u il d i n g
C
T
f
T
S e e N ote 1
T
= Flu e ter m inal
Z = Fan - a s s i ste d a p p li an c e o nly
S had in g in d i c ate s pro hi b ite d area for flu e ter m inal s
e t I
m
r o
t o
e h
s r
f r u
c a
* e
* r
g n
a
s
a p
l b
w o
r e
t u
j
h
D o or
T
n
j
h
j
T
Z
b
D ire c t i o n of
d i s c h ar g e
Min. Clearances
(mm)
Fan Assisted
200
300
300
300
1000
500
75
500
300
i
Minimum clearance 500mm to nearest part of roof
ii
300
Minimum clearance 25mm to any combustible materials
iii
Decktite or lead collar flashing
300
500
* - unless appliance is certified for closer installation
† - Prohibited area below electricity meter or fuse box extends to ground level.
1500
NOTES:
1500
1
Where dimensions c, j or k cannot be achieved an equivalent horizontal distance
1500
measured diagonally from the nearest discharge point of the terminal to the opening
may be deemed by the Technical Regulator to comply.
2
See Clause 6.9.4 for restrictions on a flue terminal under a covered area.
3
See Figure J3 for clearances required from a flue terminal to an LP Gas cylinder.
150
A flue terminal is considered to be a source of ignition.
4
For appliances not addressed above acceptance should be obtained from the
500
Technical Regulator.
1000
FIGURE 6.2 (in-part) MINIMUM CLEARANCES REQUIRED FOR FAN-ASSISTED FLUE TERMINALS,
ROOM-SEALED APPLIANCE TERMINALS AND OPENINGS OF OUTDOOR APPLIANCES
1500
20
a
e
k
P
I
k
d
e
d
g
M
T
T
S e e N ote 1
i
iii
ii
RHFE0800F_1000_1500 IM
g
T

Advertisement

Table of Contents
loading

This manual is also suitable for:

Flametech ls1500Rhfe0800fRhfe1000Rhfe1500

Table of Contents