WALL LINING INSTALLATION
NON - COMBUSTIBLE THICK WALL LININGS
Adhesive or
mechanical fixing
With Wallboard Support removed or wall
lining protruding beyond the fire front the
wall lining must be non-combustible for
at least 300 mm up wall
With Wallboard Support removed or wall
lining protruding beyond the fire front the
wall lining must be non-combustible for
at least 300 mm up wall
Adhesive or
mechanical fixing
Rinnai
Opening size
C minimum
Opening size
C minimum
No combustible materials within
50mm of top of heater engine
No combustible materials within
50mm of top of heater engine
Ensure clearance around
glass trim latches
Wallboard Support
removed
Finish Trim latches will need to
be allowed for if Finishing Trim
is going to be used
32
Backing or support board
must be non-combustible
below timber lintel line
Ensure clearance around
glass trim latches
Wallboard Support
removed
Finish Trim latches can be
removed
RHFE0800F_1000_1500 IM