Installation Configuration Warnings - Rinnai Flametech LS1000 Installation Manual

Ls - gas fireplace
Hide thumbs Also See for Flametech LS1000:
Table of Contents

Advertisement

FLUEING

INSTALLATION CONFIGURATION WARNINGS

ONLY  the  Rinnai  flue  system  components  specified  in  this  reference  manual  MUST be used.
Components NOT specified in these manuals, whether manufactured by Rinnai or otherwise, are 
NOT compatible and MUST NOT be used! Rinnai appliance warranty conditions may be voided if
WARNING
non Rinnai flue components are fitted.
Use ONLY the supplied silicone grease when lubricating the O-rings.
ONLY an authorised person MUST install, service and remove the Rinnai heater & flue system.
The maximum flue length is 8.5m 
(1) For every 90 ° bend, the overall flue length MUST be reduced by 1m.
(2) The 90° bend of the flue transition piece is NOT counted as a 90 ° bend.
LS / Flametech series heaters combustion settings are factory set for "long flue", which is for flue 
lengths that are 3 metres or greater. For flue lengths shorter than 3 metres it may be necessary to 
change dip switch setting, refer to the commissioning instructions for full details.
Note 1. When  cutting  the  flue  transition  for  joining  to  other  components  the  minimum  total 
length MUST NOT be less than 300mm!
NOTE
Note 2. The all aluminium flue extension component MUST be fitted at this point.
NOTE
Note 3. Where stipulated a Minimum 2° fall towards the terminal is required to ensure correct
drainage of condensation formed in the discharge flue.
NOTE
Note 4. Where stipulated a Minimum 2° fall towards the appliance is required to ensure correct
drainage of condensation formed in the discharge flue.
NOTE
Cut to correct
length & discard
!
See Note 3.
Cut to correct
length & discard
!
See Note 3.
DIRECT
!
See note 3.
A
!
See note 3.
Rinnai
and the maximum number of 90° bends is 3
(1)
!
See Note 1.
LSFDFK01
!
See Note 1.
LSFKIT01
ESWTERM
!
See Note 2.
!
See note 3.
A
A
Cut to correct
length & discard
!
See Note 3.
Cut to correct
length & discard
!
See Note 3.
DIRECT EXTENDED
!
See Notes 1 & 4.
LSFDFK01
18
.
(2)
See Note 1.
LSFDFK01
ESPIPE900
!
See Note 1.
LSFKIT01
ESPIPE900
!
ESWTERM
See Note 2.
!
See Notes 2 & 4.
LSFKIT01
OFFSET
RHFE0800F_1000_1500 IM
!

Advertisement

Table of Contents
loading

This manual is also suitable for:

Flametech ls1500Rhfe0800fRhfe1000Rhfe1500