5.5 Powering on device

Power on the Gazelle S1503i as below:
Step 1 The Gazelle S1503i can be powered on after being inserted with the power cable and installed
properly.
Step 2 The Gazelle S1503i is powered on when the DC power LEDs (PWR1/PWR2) or AC power
LED (PWR) is lightening up.
Step 3 The Gazelle S1503i begins to operate properly after self-check and initialization. Interface
LEDs indicate the working status of the interface (lightening up, off, or blinking).

5.6 Inspections after installation

Table 5-2 lists items to be inspected about the Gazelle S1503i after installation.

Table 5-2 Items to inspected after installation

No.
Components of the Gazelle S1503i are installed properly and do not loose or fall
1
off.
2
All screws are tightened properly.
3
Cables are connected correctly without looseness or virtual connection.
4
Wiring of signal cables is compliant with the engineering design documents.
5
Signal cables are not damaged, disconnected, or intermediately connected.
6
Labels on the two ends of the signal cable are correct, distinct, and neat.
7
Pigtail of fiber should be fit into a pipe sleeve or groove for protection and it should
not be extruded by other cables or objects when it is placed outside the cabinet.
8
The curvature radius of the fiber should be greater than 20 times of the diameter of
the fiber. In general, the curvature radius of the fiber is greater than 40 mm.
9
The power cable and grounding cable are compliant with the engineering design
documents for convenience of dilatation.
10
The power cable and signal cable should be laid out separately.
11
No stains or scratches on the Gazelle S1503i.
The insurance capacity of the power can support the Gazelle S1503i to work
12
normally as the maximum power consumption.
When making the nose of the power cable or grounding cable, you should make
13
sure that it is welded or crimped firmly.
14
The power cable and grounding cable are connected reliably and the spring shim of
the grounding terminal is placed upon the flat shim.
15
There is enough room for heat dissipation around the Gazelle S1503i and no heavy
object is placed on it.
Item
Raisecom Technology Co., Ltd.
5 Hardware installation
Method
Check
Check
Check
Check
Check
Check
Check
Check
Check
Check
Check
Instrument
detection
Check
Check
Check
41