3.2 EMC standards

The Gazelle S1503i is compliant with the following Electromagnetic Compatibility (EMC)
standards:

3.3 Environmental standards

The Gazelle S1503i is applicable to the industrial environment and environmental
requirements are as shown in Table 3-2.

Table 3-2 Environmental requirements of the Gazelle S1503i

Air pressure
Operating temperature
Storage temperature
Operating humidity
Protection level
Environmental authentication
Item
Frequency
Overload protection
Reverse connection protection
Electro Magnetic Interference (EMI) meets CISPR 22 CLASS A related requirements.
Static electricity meets IEC 61000-4-2 level 3 requirements.
Radiated Immunity Test (RIT) meets IEC 61000-4-3 level 3 requirements.
Electrical Fast Transient (EFT) meets IEC 61000-4-4 level 3 requirements.
Damped oscillation meets IEC 61000-4-12 level 3 requirements.
Surge (impact) meets IEC 61000-4-5 level 4 requirements.
Power Frequency Magnetic Field meets IEC 61000-4-8 level 3 requirements.
Pulse Magnetic Field meets IEC 61000-4-9 level 3 requirements.
Damped Oscillation Magnetic Field meets IEC 61000-4-10 level 3 requirements.
Conducted Immunity (CI) meets IEC 61000-4-6 level 3 requirements.
DC power sag or temporary interruption immunity meets IEC 61000-4-29 requirements.
AC power voltage falling and interruption meet IEC 61000-4-11 requirements.
Item
Raisecom Technology Co., Ltd.
50/60 Hz
Supported
Supported
Range
86–106 kPa
-40 to 75° C
-40 to 85° C
5%–95% RH (non-condensing)
IP40
Comply with EU RoHS standard.