Configuring the instructions

4.1

Importing add-on instructions

To program Ident systems using the Studio 5000 Logix Designer, you require add-on
instructions. You can find the add-on instructions on the DVD supplied with the RF600
readers or on the pages of the Siemens Industry Online Support
(https://support.industry.siemens.com/cs/ww/en/ps/14971/dl).
Requirement
The Studio 5000 Logix Designer was started and a project was created.
Procedure
Follow the steps below to import the add-on instructions into the Studio 5000 Logix
Designer:
1. Copy the "*.l5x" installation file locally to your PC.
You can find the file on the DVD supplied with the reader or under the provided link.
2. Open Studio 5000 Logix Designer.
3. Open the "Import Add-On Instruction" dialog ("FILE > Import Component > Add-On
Instruction").
4. Go to the "*.L5X" file and select it.
5. Confirm your entry with "OK".
Result: The add-on instructions are imported into the Studio 5000 Logix Designer:
NOTICE
Overwriting existing add-in instructions
If older versions of the add-in instructions are already included in your project, ensure
that all existing instructions ("References > Add-On Instructions") and data types
("References > Data Types") are overwritten.
Ident profile, Add-on instruction for Rockwell systems
Function Manual, 07/2020, C79000-G8976-C410-04