Warnings - Siemens SIMATIC Ident Function Manual

Hide thumbs Also See for SIMATIC Ident:
Table of Contents

Advertisement

5.1.4

Warnings

Byte 3 of the "STATUS" output parameter indicates warnings if byte 0 of the "STATUS"
(instruction numbers) has the value "Fxh" or "Dxh".
Table 5- 3
Bytes 0...2 Byte 3
FxFExxh
Ident profile, Add-on instruction for Rockwell systems
Function Manual, 07/2020, C79000-G8976-C410-04
5.1 Error messages from the Ident profile / Ident instructions
Possible warnings when working with the Ident profile
Meaning
Bit 0
The bit is always set to "0"
Bit 1
The ECC mode has corrected a 1-bit error.
Bit 2
Battery low
Bit 3
Depends on the manufacturer
Bit 4
Depends on the manufacturer
Bit 5
Depends on the manufacturer
Bit 6
Depends on the manufacturer
Bit 7
Depends on the manufacturer
Diagnostics and error messages
113