Siemens SIMATIC Ident Function Manual page 55

Hide thumbs Also See for SIMATIC Ident:
Table of Contents

Advertisement

Results
Apply the correct data type that is assigned to the ATTRIBUTE value at the
"IDENT_DATA" input of the instruction so that the data can be correctly interpreted. Only
an Array of Byte can be created at the "Ident Data" parameter . The conversion to the
corresponding data type must be done manually.
Table 4- 34 ATTRIBUTE "0x81" (data type "IID_READSTAT_81_RF2_3_U")
Name
status_info
hardware
hardware_version
loader version
firmware
firmware_version_HB
firmware version LB
driver
driver version
interface
baud
reserved1
reserved2
reserved3
distance_limiting_SLG
multitag SLG
field ON control SLG
field ON time SLG
sync SLG
status_ant
stand by
MDS_control
Table 4- 35 ATTRIBUTE "0x86" (data type "IID_READSTAT_86_RF300")
Name
status info
FZP
ABZ
CFZ
SFZ
CRCFZ
BSTAT
ASMFZ
reserved0
Ident profile, Add-on instruction for Rockwell systems
Function Manual, 07/2020, C79000-G8976-C410-04
Type
Comment
SINT
Reader status mode
SINT
Type of hardware
INT
Version of hardware
0 = RF310R, RF340R, RF350R; 1 = RF380R, RF260R; 2
= RF310R (ISO), RF210R, RF220R; 3 = RF380R (ISO),
RF240R; 4 = RF340R (ISO), RF350R (ISO), RF250R; 5
= RF310R (ISO); 8 = MV400/MV500; A = RF310R Gen2,
RF290R; B = RF340R Gen2; C = RF350R Gen2; D =
RF380R Gen2; M = RF280R RS422; N = RF280R RS232
INT
Version of loader
SINT
Type of firmware
SINT
Version of firmware
SINT
Version of firmware
SINT
Type of driver
INT
Version of driver
SINT
Type of interface
0x01 = RS422; 0x02 = RS232
SINT
Baudrate
0x01 = 19.2 kBd; 0x03 = 57.6 kBd; 0x05 = 115.2
kBd
SINT
Reserved
SINT
Reserved
SINT
Reserved
SINT
Distance limiting of Reader
SINT
Multitag Reader
SINT
Field ON control
SINT
Field On time
SINT
Synchronization with Reader
SINT
Status of antenne
0x01 = on; 0x02 = off
SINT
Time of standby after command
SINT
Presence mode
Type
Comment
SINT
Reader status mode
SINT
Error counter passive: distortion without commu-
nication
SINT
Dropout counter
SINT
Code error counter
SINT
Signature error counter
SINT
CRC-error counter
SINT
Status of last command
SINT
Error counter for host interface (ASM)
SINT[17]
Reserved
Configuring the instructions
4.5 Programming instructions
55