Siemens SIMATIC Ident Function Manual page 67

Hide thumbs Also See for SIMATIC Ident:
Table of Contents

Advertisement

Table 4- 49 Output parameter
Output parameter
DONE
ERROR
STATUS
WARNING
BUSY
RPTACT
ERR_IREQ
TPC
TP
Ident profile, Add-on instruction for Rockwell systems
Function Manual, 07/2020, C79000-G8976-C410-04
Data type
Default value
BOOL
FALSE
BOOL
FALSE
DINT
FALSE
BOOL
FALSE
BOOL
FALSE
BOOL
FALSE
BOOL
FALSE
BOOL
FALSE
BOOL
FALSE
4.6 Programming the Ident profile
Meaning
TRUE = Command was executed free of errors.
TRUE = Error was detected.
The error is output in the "STATUS" parameter. The bit is
reset automatically when a new command is started.
Warning and error
If "ERROR = TRUE" or "WARNING = TRUE", the error or
warning information is contained in the "STATUS" pa-
rameter. For more information, refer to the section
"Diagnostics and error messages (Page 103)".
TRUE = Warning was detected.
The warning is output in the "STATUS" parameter. If the
"ERROR" parameter is not set at the same time, the data
was correctly processed. The bit is reset automatically
when a new command is started.
TRUE = The instruction processes a command.
Other commands except for "INIT" and "SRESET" cannot
be started.
TRUE = "RPTCMD" is active
The acknowledgment bit shows that the "Repeat mode"
of the CM/reader is active.
TRUE = An error has occurred on the communications
module or reader (e.g. on startup of the reader, connec-
tion interruption or antenna errors with RF68xR or config-
uration changes)
Transponder Presence Changed (only when Pres-
ence_Mode is active)
TRUE = A new transponder enters the antenna field of
the reader or a transponder has left the antenna field.
The parameter is set to "FALSE" after the successful
execution of the next "INVENTORY" (0x80, 0x81, 0x87) or
"INIT" command.
Transponder Presence
TRUE = There is a transponder in the antenna field of the
reader.
Configuring the instructions
67