Configuring the instructions
4.4 Project preparation
Table 4- 7
Name
ModuleID
BaudRate
FreeportParameter --
Table 4- 8
Name
Parity
DataBits
StopBits
22
Sub-parameters of the "ReaderSlot" parameters
Value
16#2001 0002
16#2001 1002
16#2000 8002
16#01
16#03
16#04
16#0A
Sub-parameters of the "FreeportParameter"
Value
0
1
2
3
4
7
8
1
Meaning
Description
General reader
Selection of the desired Ident sys-
tem (ID of the module)
RF300 fast protocol
Freeport
19.2 kBd
Selection depends on the Ident
device/system being used. With
57.6 kBd
this parameter, you set the data
115.2 kBd
transmission speed between the
921.6 kBd
communication module and the
reader.
--
Details on this parameter are pro-
vided in the table below.
Meaning
Description
None
Parity selection
A sequence of data bits can be
Even
expanded by a parity bit. With its
Odd
value "0" or "1", the parity bit is
Fixed value 1
added to the sum of all bits (data
bits and parity bits) to form a de-
Fixed value 0
fined status. This increases data
reliability.
--
Selection of the number of bits to
which a character is mapped.
--
--
Selection of the number of stop bits
Ident profile, Add-on instruction for Rockwell systems
Function Manual, 07/2020, C79000-G8976-C410-04
None:
Data is sent without a parity bit.
Even:
The parity bit is set so that the
sum of the data bits (including
the parity bit) is even when the
signal state is "1".
Odd:
The parity bit is set so that the
sum of the data bits (including
the parity bit) is odd when the
signal state is "1".
Fixed value 1:
The parity bit is set permanently
to the value "1".
Fixed value 0:
The parity bit is set permanently
to the value "0".