Diagnostics and error messages
5.1 Error messages from the Ident profile / Ident instructions
Error mes-
Description
sage
(hex)
0xE6FE0300
The communication module or reader was configured incorrectly.
Possible causes / action to be taken:
Check the "INPUT" parameters in the Ident profile.
Check the hardware configuration.
"WRITE-CONFIG" command has incorrect parameter settings.
After a startup, the reader or communications module has still not received an "INIT".
The parameter assignment of the reader or communications module on PROFIBUS/PROFINET
was incorrect and the command cannot be executed.
Possible causes / action to be taken:
Length of the input/output areas too small for the cyclic I/O word.
Correct GSD file being used?
User data length set with command (e.g. "READ") too high.
Error when processing the command
Possible causes / action to be taken:
Bad data in the "AdvancedCmd" or "IID_CMD_STRUCT" (e.g. "WRITE" command with length =
0); check "AdvancedCmd" or "IID_CMD_STRUCT" and execute "INIT".
Reader/communications module hardware defective: The reader or communications module
receives bad data with "INIT".
Inconsistent length specifications in the command
Wrong reset block was selected.
Possible causes / action to be taken:
Use the reset block suitable for the Ident device.
0xE6FE0400
Presence error
A transponder has passed through the transmission window of a reader without being processed.
This error message is not reported immediately. Instead, the reader or communication module
waits for the next write / read command. This command is replied to immediately with this error
and the write/read command is not executed. The next command is executed normally again by
the reader/communication module.
You can reset this error status using an "INIT".
0xE6FE0500
An error has occurred that makes a Reset_Reader ("WRITE-CONFIG" with "Config = 3") necessary.
Possible causes / action to be taken:
The "WRITE-CONFIG" command is incorrect.
After eliminating the error, execute an "INIT".
Check the parameter "IID_HW_CONNECT".
0xE6FE8100
A parameter is missing.
0xE6FE8200
The parameter has an invalid format.
0xE6FE8300
The parameter type is invalid.
0xE6FE8400
Unknown parameter
0xE6FE8500
The command or the frame has an invalid format.
0xE6FE8600
The "Inventory" command failed.
110
Ident profile, Add-on instruction for Rockwell systems
Function Manual, 07/2020, C79000-G8976-C410-04