Mahindra XUV700 2021 Diagnostic Manual page 48

Table of Contents

Advertisement

Diagnostic Manual
XUV700 (Diesel)
13.4.2 DIAGNOSTIC PROCEDURE
STEP 1 – TRY STARTING THE VEHICLE WITH THE SECOND KEY
PRE CONDITION
• Turn ON ignition with second key
TEST PROCEDURE
• Check whether Immobilizer check lamp and Engine check lamp is blinking
ACCEPTANCE CRITERIA
• Check lamp's should be OFF and vehicle should start
• Replace the other key or first key
The repair methods given by the manufacturer in this document are based on the technical specifications, current at the time of release. The methods may be modified as a result of changes introduced by the
manufacturer in the production of the various component units and accessories from which the vehicles are manufactured. The reproduction, translation, transmission, in part of or whole of the present document, are
48
prohibited without the prior written consent of Mahindra & Mahindra Ltd. The use of this document by any person other than the trained personnel, at the Authorized Service Centre of Mahindra & Mahindra Ltd., will
amount to unauthorized use and shall be liable for penalty/prosecution© 2021 Mahindra & Mahindra Ltd.
UICU
ACTION TO BE TAKEN
OK
NOT OK
• Replace both keys with new one and
perform key assignment
Always use i-SECURE+ V4.0.7 and
above
for
any
components ECU programming in
"XUV 7OO"
• If the issue still persist, replace the
immobilizer
with
perform ICU assignment
MAN-01065
OCT - 2021/Rev 1
security
new
one
and