Every 2 Years / Every 500 Operating Hours; Changing The Hydraulic Oil - Fayat DYNAPAC DRP40DX Operating Instructions Manual

Reversible vibratory plate
Table of Contents

Advertisement

Maintenance – Every 2 years / every 500 operating hours
8.10

Every 2 years / every 500 operating hours

8.10.1

Changing the hydraulic oil

Fig. 97
Fig. 98
Fig. 99
90
Protective equipment:
1.
Park the machine in secured condition
„Parking the machine in secured condition" on page 55.
2.
Adjust the steering rod with height adjustment so that the
area with the filler screw is horizontal.
3.
Unscrew the filler screw.
4.
Press the handle forward against the stop and secure it using
suitable means.
5.
Unscrew the bleeding screw and collect any oil running out.
6.
Screw in the bleeding screw.
DRP40DX
n
Working clothes
n
Protective gloves
Ä Chapter 6.4

Advertisement

Table of Contents
loading

Table of Contents