Maintenance – Every 2 years / every 500 operating hours
8.10
Every 2 years / every 500 operating hours
8.10.1
Changing the hydraulic oil
Fig. 97
Fig. 98
Fig. 99
90
Protective equipment:
1.
Park the machine in secured condition
„Parking the machine in secured condition" on page 55.
2.
Adjust the steering rod with height adjustment so that the
area with the filler screw is horizontal.
3.
Unscrew the filler screw.
4.
Press the handle forward against the stop and secure it using
suitable means.
5.
Unscrew the bleeding screw and collect any oil running out.
6.
Screw in the bleeding screw.
DRP40DX
n
Working clothes
n
Protective gloves
Ä Chapter 6.4