Semi-Annually; Battery Service - Fayat DYNAPAC DRP40DX Operating Instructions Manual

Reversible vibratory plate
Table of Contents

Advertisement

Maintenance – Semi-annually

8.8 Semi-annually

8.8.1 Battery service

Fig. 56
1
5
6
Fig. 57
74
B-SYM-1077
Protective equipment:
1.
Park the machine safely
in secured condition" on page 55.
2.
Remove the bracket (1) of the battery.
2
3.
Remove the battery (3) and the vibration damping mats (2, 4,
5, 6).
4.
Check the condition of the vibration insulation mats, replace if
3
necessary.
4
5.
Clean the outside of the battery.
6.
Clean battery poles and pole clamps and grease them with
pole grease (Vaseline).
B-692-0066
7.
On serviceable batteries check the acid level, if necessary
top up to the filling mark with distilled water.
8.
Install battery and vibration insulation mats.
9.
Install the bracket of the battery.
DRP40DX
Maintenance free batteries also need care. Mainte-
nance free only means that the fluid level does not
need to be checked.
Every battery has a self-discharge, which may, if
not checked occasionally, even cause damage to
the battery as a result of exhaustive discharge.
Exhausted batteries (batteries with formation of
sulphate on the plates) are not covered under war-
ranty!
n
Working clothes
n
Safety shoes
n
Protective gloves
n
Safety goggles
Ä Chapter 6.4 „Parking the machine

Advertisement

Table of Contents
loading

Table of Contents