Oil For Exciter Shaft Housing; Mineral Oil Based Hydraulic Oil - Fayat DYNAPAC DRP40DX Operating Instructions Manual

Reversible vibratory plate
Table of Contents

Advertisement

Maintenance – Fuels and lubricants
8.3.2.2
Winter fuel
8.3.2.3
Storage

8.3.3 Oil for exciter shaft housing

8.3.4 Mineral oil based hydraulic oil

66
For winter operation use only winter diesel fuel, to avoid clogging
because of paraffin separation.
At very low temperatures disturbing paraffin separation can also be
expected when using winter diesel fuel.
Diesel fuels suitable for temperatures down to -44 °C (-47 °F) are
available for Arctic climates.
NOTICE!
Danger of engine damage!
The admixture of petroleum and the addition of
"flow enhancing additives" (fuel additives) is
not permitted.
Even traces of zinc, lead and copper can cause deposits in the
injection nozzles, especially in modern Common-Rail injection sys-
tems.
Zinc and lead coatings in refuelling systems and fuel lines are not
permitted.
Copper containing materials (copper lines, brass items) should be
avoided, because they can cause catalytic reactions in the fuel with
subsequent depositing in the injection system.
Use only engine oils according to the following specifications:
n
API CI-4 or higher quality
Avoid mixing engine oils.
NOTICE!
Components may get damaged!
Do not use low-ash engine oils for the exciter
shaft housing.
The hydraulic system is operated with hydraulic oil HV 32 (ISO)
with a kinematic viscosity of 32 mm
When refilling or changing oil, use only hydraulic oil type HVLP
according to DIN 51524, part 3, or hydraulic oil type HV according
to ISO 6743/4.
DRP40DX
2
/s at 40 °C (104 °F).