8.9.8 Replacing the starter rope

Fig. 88
Fig. 89
Fig. 90
Maintenance – Annually / every 250 operating hours
Protective equipment:
1.
Park the machine in secured condition
„Parking the machine in secured condition" on page 55.
2.
Allow the engine to cool down.
3.
Unscrew the fastening screws (1) and disassemble the recoil
starter (2).
4.
Pull the starter rope with the starter handle (1) out com-
pletely.
5.
Secure the coil (2) against winding up.
6.
Loosen the knot (3) in the starter rope and remove the old
starter rope.
7.
Carefully turn the coil back, until the recoil spring is relieved.
8.
Thread in the new starter rope and fix it with knots on both
ends .
A = 15 mm (0.6 in)
DRP40DX
n
Working clothes
n
Protective gloves
Ä Chapter 6.4