Maintenance – As required
8.11

As required

8.11.1

Cleaning the machine

Fig. 104: Cleaning the machine
(example)
8.11.2

Cleaning the cooling fins and the cooling air intake openings

Fig. 105
92
Protective equipment:
1.
Park the machine in secured condition
„Parking the machine in secured condition" on page 55.
2.
Allow the engine to cool down for at least 30 minutes.
3.
NOTICE!
Electric components can be damaged by
water entering into the system!
Do not guide the water jet directly into the
cooling air openings of the recoil starter,
into the dry air filter or onto electrical
equipment.
Clean the machine from the outside and inside with a water
jet.
4.
Warm up the engine for a while to avoid corrosion.
How dirty the cooling fins and cooling air intake
openings are depends very much on the daily
operating conditions; clean daily if necessary.
Protective equipment:
1.
Park the machine in secured condition
„Parking the machine in secured condition" on page 55.
2.
Allow the engine to cool down.
3.
Remove dried dirt with a suitable brush from all cooling fins
and cooling air intake openings.
4.
CAUTION!
Danger of eye injuries caused by particles
flying around!
Wear your personal protective equipment
(safety gloves, protective working
clothes, goggles).
Blow out the cooling fins and cooling air intake openings with
compressed air.
DRP40DX
n
Working clothes
n
Protective gloves
Ä Chapter 6.4
n
Working clothes
n
Protective gloves
Safety goggles