8.11.3

Servicing the V-belt

Fig. 106
Fig. 107
Fig. 108
5.
In case of damp or oily contamination you should consult our
customer service department.
Protective equipment:
1.
Park the machine in secured condition
„Parking the machine in secured condition" on page 55.
2.
Allow the engine to cool down.
3.
Unscrew the V-belt guard (1).
4.
Check condition and tension of V-belt.
ð Compression measurement: 10 - 25 mm
(0.59 - 0.98 in).
5.
The V-belt cannot be re-tightened.
Replace the V-belt if it is damaged or if the compression
measurement is exceeded
belt" on page 75.
6.
Fasten the V-belt guard (1).