6.4 Parking the machine in secured condition

Fig. 38
Fig. 39
Fig. 40
Operation – Parking the machine in secured condition
1.
Park the machine on level and firm ground.
2.
Set the throttle lever to "MIN" position (idle speed).
ð Vibration is shut down.
3.
Set the throttle lever to position "Stop".
ð The engine is shut down.
The warning buzzer sounds.
4.
Turn the ignition key to position "0" and pull it out.
ð The warning buzzer stops.
DRP40DX
NOTICE!
Danger of engine damage!
Do not shut down the engine all of a
sudden from full load speed, but let it idle
for about two minutes.