Lubricating The Machine - Fayat DYNAPAC DRP40DX Operating Instructions Manual

Reversible vibratory plate
Table of Contents

Advertisement

8.9.9 Lubricating the machine

Fig. 94
3
Grease
Fig. 95
Fig. 96
Maintenance – Annually / every 250 operating hours
Protective equipment:
1.
2.
2
1
B-692-0245
3.
2
1
B-692-0186
4.
2
1
B-692-0245
n
Working clothes
n
Safety shoes
n
Protective gloves
Park the machine safely
in secured condition" on page 55.
Unscrew the four fastening screws (1) and remove the cover
(2).
NOTICE!
Inadequate lubrication will cause damage
to components!
Use only grease of the permitted specifi-
cation.
(Spare parts number of lubrication
grease: DL 009 960 17)
Grease the mechanical parts between the fork head (1), lever
(2) and bolt (3).
Fasten the cover (2) with four fastening screws, tightening
torque: 10 Nm (7.5 ft·lbf).