Section 5: Display Options; Option 21 - Display Zones (Quick Menu Option 3) - Honeywell Galaxy 3-48C Programming Manual

Hide thumbs Also See for Galaxy 3-48C:
Table of Contents

Advertisement

Galaxy 3 Series Programming Manual

Section 5: Display Options

Option 21 – Display Zones (Quick Menu Option 3)
Selecting and entering the Display Zones option shows the first zone on the system. Other zones may be
viewed by pressing the A and B keys or by entering the zone number directly.
The top line displays:
the address;
the group assigned — if the group mode is enabled. Only the zones assigned to the user's group are
displayed.
the zone function alternating with the status — open, closed, high resistance, low resistance, tamper short
or tamper open circuit or masked.
The bottom line shows:
the zone descriptor (if used);
by pressing the # key the bottom line changes to show the circuit resistance in Ohms, if using a hardwired
RIO and the RIO (not zone) voltage, pressing the # key returns the bottom line to the zone descriptor.
A printout of all the zones is available from this option by pressing the
printout.
NOTE: A serial printer must be connected to the Galaxy panel via a printer interface module, an RS232
interface module, or the on-board RS232 serial port.
21 - Display Zones
key; pressing the esc key aborts the
17

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Galaxy 3-144Galaxy 3-144cGalaxy 3-520Galaxy 3-520c

Table of Contents