51 - Parameters (cont'd)
66 = Min Pin Size
This parameter determines the minimum size of each user code. This can be set from four to six digits. The
default is five digits.
67 = Level Format
This parameter determines the format used for user code authorization levels.
1 = EN.Galaxy (Default)
Uses new EN Galaxy user types 1.0 to 3.8.
2 = Galaxy
Uses standard Galaxy levels 0-8.
68 = Line Fail
This parameter allows the programming of the period between the panel being alerted by a communication
module of a Line Fail condition, and the user being alerted of the alarm condition. This value can be pro-
grammed between 0 and 1800 seconds. The default is 50 seconds.
NOTE: The communication module may take up to 40 seconds to alert the panel of a Line Fail condition.
This time is in addition to the programmed time of 0-1800 seconds.
This parameter affects all communication modules on the system.
69 = Alert Inds
This parameter allows the alert audio indication to be switched off. The default is 1 = Audio only.
0 = No Indication
1 = Audio Only
2 = Visual Only (only when parameter 63 enabled)
3 = Audio/Visual (only when parameter 63 enabled)
70 = SWDC Set Dly
When enabled, this parameter delays the indication of open zones at the start of a set sequence whilst the
Switch DC output (53.08) is active; this includes keypad text and sounders.
If there are no outputs programmed as Switch DC then there will be no delay at the start of the set.
71 = MF BL Enable
When enabled, this parameter allows the panel to send a SIA event when the battery is low and there is a
mains power failure. When the event is sent, the Power Delay time set in parameter 51.20 stops immediately.
72 = Max Alm Cause
This option defines the range of valid cause codes, as agreed with the Alarm Receiving Centre. When this
function is enabled, a cause code must be entered by the user when a reset of the system is required.
This parameter can be disabled by setting the alarm cause code to 000.