Honeywell Galaxy 3-48C Programming Manual page 90

Hide thumbs Also See for Galaxy 3-48C:
Table of Contents

Advertisement

52 - Program Zones (cont'd)
38 PA Unset
This PA Unset function is identical to the PA Silent function, with the exception that it is only operational
when the system is unset; the function is inactive when the group is set.
39 Keyswitch Reset
The Keyswitch Reset function allows alarms to be cancelled and the system to rearm without unsetting the
Galaxy. The type of reset authorization is determined by the Keyswitch Level (option 51.14). The type
required to reset Intruder, PA and Tamper alarms is determined by the System Reset, Tamper Reset
and PA Reset parameters (option 51.06, 51.07 and 51.22) respectively.
This function is designed to permit a remote signal, for example REDCare's Return Path Signalling feature, to
reset the system following an alarm condition.
40 Bell Fail
This zone type is intended for bells which have diagnostic capabilities and failure outputs. If activated, this zone
causes a fault condition.
41 Intr Low
This zone type assigns a low priority to a zone in the event of an intruder alarm. The event is logged as low
priority in the event log.
42 Intr High
This zone type assigns a high priority to a zone in the event of an intruder alarm. The event is logged as high
priority in the event log.
43 PSU Fault
This zone type triggers a general fault output and logs a PSU fault in the event log. The fault is signalled to the
ARC as YP when using SIA format and 314 when using CID format.
44-46
Not used
47 Vibration
The Vibration function is continuously operational and is designed for use with vault sensors. Vibration
zones can be block omitted using menu option 11 = Omit Zones. If the zone selected to be omitted from the
system is a Vibration zone, then all zones programmed with this function are omitted.
NOTES
1. All Vibration zones in all groups are omitted when any Vibration zone is omitted. The user code does
not have to have access to all of the groups.
2. Vibration zones remain omitted until a single Vibration zone is manually reinstated. The unsetting of the
system does not reinstate omitted Vibration zones.
Galaxy 3 Series Programming Manual
84

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Galaxy 3-144Galaxy 3-144cGalaxy 3-520Galaxy 3-520c

Table of Contents