Honeywell Galaxy 3-48C Programming Manual page 85

Hide thumbs Also See for Galaxy 3-48C:
Table of Contents

Advertisement

Galaxy 3 Series Programming Manual
52 - Program Zones (cont'd)
13 PA
The PA (Personal Attack) function is continuously operational. Activation of this zone type overrides the Bell
Delay parameter and causes an instant full alarm condition that requires to be reset with a code authorized for
PA Reset — refer to Option 51 – PARAMETERS, 22 = PA Reset; the Intruder outputs are not acti-
vated by PA zones.
NOTE: If a PA zone is open, it is indicated on the keypad whenever a valid code is entered. The group that
the open PA is assigned to cannot be set until it is closed.
14 PA Silent
The PA Silent function is identical to the PA function, with the exception that there is no audible or visual
indication of the activation; that is, no bells or strobes are activated. Only the PA output (normally channel 2
on the digital communicator) signals the alarm. The activation (+) and restoral (–) of PA Silent zones is
recorded in the event log.
NOTES
1. At the time of setting, any PA Silent zones that are currently open are reported to the user.
2. The tamper facility on the PA zone remains active while engineer mode is accessed.
3. Engineer mode cannot be exited if a PA Silent zone is open.
15 PA Delay
The PA Delay function is identical to the PA function, with the exception that the PA output activation can be
delayed for up to 60 seconds; this is determined by option 51.13 = PARAMETER.PA Delay. During the
period of delay the Entry/Exit Horns activate to remind the user that the PA delay is counting down; entering
a valid code or closing the PA Delay zone aborts the alarm.
NOTES
1. If a PA Delay zone is open, it is indicated on the keypad whenever a valid code is entered. The group
that the open PA Delay is assigned to cannot be set until it is closed.
2. The tamper facility on the PA zone remains active while engineer mode is accessed.
16 PA Delay Silent
The PA Delay Silent function is identical to the PA Delay function, with the exception that there is no audible
or visual indication of the activation; that is, no bells or strobes are activated. Only the PA output (normally
channel 2 on the digital communicator) signals the alarm. The activation (+) and restoral (–) of PA Delay
Silent zones are recorded in the event log.
NOTES
1. At the time of setting, any PA Delay Silent zones that are currently open are reported to the user.
2. The tamper facility on the PA zone remains active while engineer mode is accessed.
79

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Galaxy 3-144Galaxy 3-144cGalaxy 3-520Galaxy 3-520c

Table of Contents