Honeywell Galaxy 3-48C Programming Manual page 104

Hide thumbs Also See for Galaxy 3-48C:
Table of Contents

Advertisement

Galaxy 3 Series Programming Manual
53 - Program Outputs (cont'd)
33 Warning (Latch)
The Warning output is activated by the first occurrence of a high (1200-1300Ω) and low (800-900Ω)
resistance reading on each of the system zones in a single 24 hour period: the activating zone is recorded in the
log.
NOTE: The time period finishes at midnight, not 24 hours from first activation.
Subsequent high and low resistance readings from the same zone on the same day do not activate the output if
it has been reset by a valid user code.
NOTE: If a low resistance reading is followed by a high resistance reading, the Warning output activates on
the first occurrence of both activations.
34 Custom A (Latch)
The Custom-A output is activated whenever a Custom-A zone is activated.
35 Custom B (Latch)
The Custom –B output is activated whenever a Custom-B zone is activated.
36 Test (Pulse)
The Test output is activated at 12:00 hours each day for two seconds – the period of the Pulse can be
altered. This output can be used to perform a daily test on a digicom connected to the system.
37 Reset RQD (Latch)
The Reset RQD output is activated when a system, tamper or PA alarm has occurred that requires to be
reset by the engineer (type 3.7) code. Refer to option 51=PARAMETERS for details modifying the code
types assigned to the 06=System Reset, 07=Tamper Reset and 22=PA Reset parameters.
38 Mask (Latch)
The Mask output is activated whenever the zone resistance values returned by the RIO to the panel fall within
the range of the masked state (see Parameter 51.46, Zone Resistance). The output is not subject to the
Rearm parameter: It latches on and remains active until a valid group code (type 2 or above) is entered.
39 Valid Code (Reflex)
The Valid Code output is activated by the entry of any valid code. If the Output Mode assigned is Reflex,
the output remains active while the user is accessing the menu and setting and unsetting the system. Once the
menu is exited or the system sets or unsets, the output is restored.
40 Fail Set (Latch)
The Fail Set is activated if the system (or assigned groups) fails to set within the time assigned in parameter
35=Fail to Set – refer to option 51=PARAMETERS.
41 Duress (Latch)
The Duress function is activated on entry of a Duress Code (any valid code followed by two #'s, or a code
assigned as a Duress Code using menu option 42 – Codes). The output is not subject to the Rearm param-
eter: it latches on and remains active until a valid code (type 2 or above) is entered.