Galaxy 3 Series Programming Manual
KEYPAD TEXT
+ FINAL
Final zone activated (opened) during Setting/Unsetting procedure or when Set.
– FINAL
Final zone de-activated (closed) during Setting/Unsetting procedure or when Set.
FIRE
Fire zone activated (opened).
FOB REJCT
Illegal fob
FORCE OMT
Force Omit of a zone (Menu Option 14).
FULL SET
Full Set (Menu Option 12) of the system or Group(s).
FULL TEST
Full Test (Menu Option 62) has occurred.
FUSE 14.5
Fault with 14.5V fuse on Power Supply Unit
FUSE AUX1
Fault with AUX1 fuse on Power Supply Unit
FUSE AUX2
Fault with AUX2 fuse on Power Supply Unit
FUSE BELL
Fault with Bell Fuse on Power Supply Unit
GRP OMIT +
Group Omit has occurred (Group(s) has been omitted).
GRP OMIT –
Group Omit has finished (Group(s) has been un-omitted).
HIGH RES +
Zone changing to High Resistance (1200 to 1300 Ohm) Engineer Log only.
HIGH RES –
Zone changing from High Resistance to Normal Closed (1300 to 1200 Ohm) Eng. Log only
ILL -CODE
Illegal code entry
INST SET+
Instant set odf system or group
INTRUDER
Intruder zone activated (opened)
INT DELAY
Intruder delay zone activated (opened)
INVALD CD
Invalid Code entered
JAM DELAY
RF jam signal sent to panel
KEYSWITCH
Keyswitch zone activated (opened)
KSW CANCL
Keyswitch Cancels alarm activation (system or Group(s) still Set).
KSW P/SET
Keyswitch part sets the system or group(s)
KSW RESET
Keyswitch resets the system or group(s)
KSW SET
Keyswitch full sets the system or group(s)
KSW UNSET
Keyswitch unsets the systems or group)s)
LATE SET
Late Set of the system or group(s)
LEGAL CD
Legal code entered
LF RESET
Line Fail Reset has occured
LID TAMP
Lid Tamper alarm
Line Fail +
Comms Module Line fail has occured or a Line Fail zone activated (opened)
Line Fail -
Comms Module Line fail has finished or a Line Fail zone de-activated (closed)
+ Link
Link zone activated (opened)
- Link
Link zone de-activated (closed)
NOTE:
M = Mandatory. NM = Non-Mandatory
NOTE:
A plus (+) means an event has started. A negative (-) means an event has finished.
DESCRIPTION
D-3
Event Log (cont'd)
Trigger Event
7. Set Fault
7. Set Fault
6. Fire
None
8. Omit
10. Setting
None
13. Elec. Status
20. Fault
9. Tamper
13. Elec. Fault
9. Tamper
13. Elec. Status
9. Tamper
13. Elec. Status
8. Omit
8. Omit
15. Trouble
15. Trouble
16. Log Zone
None
2. Intruder
18. Zone restoral
None
None
None
None
11. Reset/Cancel
10. Setting
None
10. Setting
10. Setting
10. Setting
16. Log Zone
20. Fault
9. Tamper
12. Modules/Comms
20. Fault
12. Modules/Comms
20. Fault
16. Log Zone
16. Log Zone
NM
NM
M
M
M
M
NM
M
M
M
M
M
M
M
M
NM
NM
M
M
NM
M
NM
NM
M
NM
M
M
NM
NM
NM
M
M
M
NM
NM

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Galaxy 3-144Galaxy 3-144cGalaxy 3-520Galaxy 3-520c

Table of Contents