04 Receiver
The transmission destination can be set to one of three modes:
1 = Single
Reports to the telephone number programmed in Telephone Number 1.
2 = Dual
Reports to both numbers programmed in Telephone Number 1 and Telephone Number 2. The alarm must
be transmitted to both numbers.
3 = Alternate
Reports to Telephone Number 1 OR Telephone Number 2. Each number is tried in sequence until the
alarm is successfully transmitted. The alarm is only transmitted to one number. Telephone number 1 is always
the first number attempted.
05 Telephone No. 2
A second telephone number is available to support Dual and Alternate dialling to a second destination
receiver. The programming is identical to Telephone Number 1.
The B key is used to erase an existing number. Each press deletes the last digit displayed.
06 Dial Type
The transmission mode can be selected from two types:
1. Tone (also known as "DTMF Dial") this is much quicker at dialling than the Pulse option.
2. Pulse (also known as "Rotary" or "Loop Disconnect") is universal, however, an increasing number of
exchanges now provide the Tone (DTMF Dial) option.
NOTE: If unsure of the type of exchange that the panel is connected to, leave as Pulse dialling.
07 Autotest
An engineer test can be automatically transmitted to the Monitoring Station at programmed intervals, in order
to indicate alarm transmission path integrity.
1 = Start Time
The engineer uses this option to enter the time that the first engineer test is transmitted. Subsequent engineer
test transmissions are offset by the value assigned in the Test Interval option.
2 = Intervals
This option determines the period between engineer test transmissions following the Start Time, the program-
mable range is 0 – 99 hours.
NOTES:
1. If the Test Interval is 0 (default) the Autotest is disabled — even if a Start Time has been assigned.
2. To disable Autotest enter 00:00 (default); no transmissions of test signals can be sent at midnight.
56 - Communications (cont'd)